| The Concealed Ceiling Fan Coil Unit (FCU) is an advanced hydronic climate solution engineered for seamless integration into false ceilings. Designed with an ultra-slim compact profile, it delivers high-efficiency cooling and heating while remaining completely invisible, preserving the interior aesthetics of modern residences, luxury hotels, and commercial spaces. Featuring whisper-quiet operation, optimized airflow distribution, and precise temperature regulation, this unit ensures superior indoor comfort with minimal energy consumption. It offers flexible duct connections and easy maintenance access, making it the ideal choice for silent, discreet, and reliable year-round climate control. | |||||||||
Hide Ceiling Fan Coil
Nulite New Energy
The Concealed Ceiling Fan Coil Unit (FCU) is an advanced hydronic climate solution engineered for seamless integration into false ceilings. Designed with an ultra-slim compact profile, it delivers high-efficiency cooling and heating while remaining completely invisible, preserving the interior aesthetics of modern residences, luxury hotels, and commercial spaces. Featuring whisper-quiet operation, optimized airflow distribution, and precise temperature regulation, this unit ensures superior indoor comfort with minimal energy consumption. It offers flexible duct connections and easy maintenance access, making it the ideal choice for silent, discreet, and reliable year-round climate control.
This horizontal concealed fan coil unit adopts high-precision copper tubes and hydrophilic aluminum fins with mechanical expansion technology, achieving a heat exchange efficiency of up to 92%. The optimized counterflow air and water structure eliminates temperature dead zones, ensuring fast and uniform cooling and heating for indoor spaces all year round.
Equipped with a customized silent DC fan motor and multi-layer sound-absorbing insulation materials, the concealed FCU runs stably with a noise level as low as 36dB(A). The optimized impeller and air duct structure reduces air friction, providing quiet and comfortable air conditioning for homes, offices and commercial venues.
Featuring an advanced DC brushless motor and intelligent FOC vector control system, this hidden fan coil realizes stepless speed regulation. It reaches a 99% maximum power factor and saves over 50% energy compared with traditional AC models, greatly reducing long-term operation costs.
4. Slim Compact & Space-saving Concealed Design
With an ultra-slim body thickness of only 200mm, this ceiling concealed fan coil fits perfectly into narrow ceiling spaces. The integrated compact structure saves 50% installation space than exposed units, realizing invisible installation without damaging indoor overall decoration style.
5. Strict Factory Testing & Reliable Durability
All horizontal concealed fan coil units undergo 3.3MPa underwater air tightness leakage test and 100% full-load operation inspection. Complying with CE and ISO industry standards, the galvanized steel shell is anti-corrosion and rust-proof, with a service life of more than 15 years.
6. Flexible Installation & Easy Maintenance
Supporting left and right universal piping connection and multi-speed fan adjustment, this duct fan coil adapts to various installation scenarios. It is equipped with a detachable high-density filter and open maintenance window, making daily cleaning and after-sales maintenance quick and convenient.
1. What are the main advantages of horizontal concealed fan coil units?
The unit features a slim hidden design to keep ceiling aesthetics. It delivers quiet operation, individual zone temperature control, and both cooling & heating functions, widely used in commercial and residential spaces.
2.Is condensate water drainage a key point during installation?
Yes. The condensate pipe must maintain proper slope to drain water smoothly. A water filling test is required after piping to avoid condensate leakage and ceiling damage.
3. Can this fan coil work with different central chiller & heating systems?
It is compatible with most conventional central chilled water and hot water systems. Please match the water flow rate and pressure drop with your host unit before selection.
4. How to reduce operating noise of the concealed fan coil unit?
Use damping hangers and flexible connections for pipes and air ducts. Keep the unit well-leveled. Regular cleaning of the filter also helps lower abnormal noise.
5. What routine maintenance is needed for horizontal concealed fan coils?
Clean the air filter regularly to maintain airflow. Inspect pipe joints for leakage and check fan operation annually. Replace worn parts to guarantee stable performance.
Model name:NL-FP | 34HC | 51HC | 68HC | 85HC | 102HC | 136HC | 170HC | 204HC | 238HC | |
nominal air volume(m3/h) | high | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
middle | 260 | 390 | 520 | 650 | 780 | 1040 | 1290 | 1580 | 1820 | |
low | 180 | 270 | 360 | 450 | 530 | 710 | 890 | 1060 | 1240 | |
Cooling capacity (w) | high | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
middle | 1620 | 2450 | 3240 | 4050 | 4850 | 6480 | 7980 | 9580 | 11200 | |
low | 1430 | 1990 | 2650 | 3220 | 3820 | 5140 | 6400 | 7480 | 8960 | |
Heating capacity (w) | high | 2700 | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 |
middle | 2450 | 3680 | 4860 | 6120 | 7275 | 9980 | 11960 | 14200 | 16520 | |
low | 2160 | 3240 | 4300 | 5200 | 6400 | 8600 | 9200 | 10800 | 12960 | |
Conventional type noise dB(A) | ≤35 | ≤36 | ≤38 | ≤40 | ≤43 | ≤44 | ≤45 | ≤46 | ≤49 | |
High static press noisiness dB(A) | ≤39 | ≤41 | ≤43 | ≤45 | ≤48 | ≤49 | ≤50 | ≤52 | ≤54 | |
Input power (w) | Standard type | 41 | 54 | 65 | 82 | 98 | 132 | 168 | 206 | 247 |
Overpressure type | 45 | 58 | 76 | 89 | 110 | 165 | 195 | 228 | 273 | |
Outlet static press of unit(Pa) | 12Pa,30Pa,50Pa | |||||||||
Electric power | Signal phase 220v 50HZ | |||||||||
thermal sink | louvered aluminum thermal sink, spacing of fins is 2.2mm | |||||||||
No. of wind wheel(n) | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | |
Heat exchanger | Model | 3-row aluminum | ||||||||
Structure model | copper stringing roll aluminum fin | |||||||||
working pressure | 1.2Mpa | |||||||||
water pipe branching | DN20 pipe | |||||||||
condensed water connecting hose | DN20 pipe | |||||||||
water volume (kg/h) | 350 | 480 | 680 | 780 | 910 | 1140 | 1270 | 1320 | 1460 | |
hydraulic resistance (kpa) | 15 | 20 | 30 | 35 | 45 | 35 | 35 | 38 | 40 | |
Weight(kg) | Horizontal concealed(WA) | 16 | 19 | 21 | 22 | 23 | 25 | 35 | 38 | 45 |
Note: 1.all horizontal concealed type can be equipped with overpressure type(20Pa-30Pa),input power improves 1.5 times than the same grade fan coil with no overpressure. 2. The input power means those in high-level air volume. | ||||||||||