English
Home » Products » Fan Coil Units (FCU) » OEM/ODM WIFI Heating Cooling Floor Standing Fan Coil Unit for Heat Pump & Chiller System

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

OEM/ODM WIFI Heating Cooling Floor Standing Fan Coil Unit for Heat Pump & Chiller System

Availability:
Quantity:
Floor standing fan coil unit is a terminal equipment for central air conditioning water system. It can realize cooling and heating by circulating chilled or hot water inside the coil. Available in exposed or cabinet type, it requires no ceiling space for installation. Featuring simple structure, easy maintenance and independent temperature control, it is widely applied in offices, guest rooms and renovation projects where concealed installation is unavailable.
  • Floor Standing Fan Coil

  • Nulite New Energy

vertical_fan_coil_unit_ai_2010x782.png

Floor standing fan coil unit is a terminal equipment for central air conditioning water system. It can realize cooling and heating by circulating chilled or hot water inside the coil. Available in exposed or cabinet type, it requires no ceiling space for installation. Featuring simple structure, easy maintenance and independent temperature control, it is widely applied in offices, guest rooms and renovation projects where concealed installation is unavailable.

Product Advantage

high_efficiency_heat_exchange_coil_1672x1672
High-efficiency heat exchange coil

Adopts seamless copper tubes with hydrophilic aluminum fins. All coils pass 3.3MPa hydraulic pressure leakage test. Heat exchange efficiency rises by 18%, supporting fast cooling and heating for hydronic fan coil systems.

Flexible exposed floor-mounted installation

This vertical exposed FCU needs no ceiling space, ideal for renovation projects. It supports 2-pipe and 4-pipe water systems, matching chillers, air source heat pumps and boiler HVAC terminals.

img-mv20rssy-76282be4
img-mv20yqjd-bbaa651b
Ultra-low noise & stable fan performance

Dynamic balanced fan wheel reduces vibration. Sound level can reach as low as 28dB(A). 3 adjustable fan speeds deliver stable airflow, making this low noise floor mounted fan coil suitable for offices and hotel rooms.

product_feature_banner_2010x782.png

4. Robust structure & convenient maintenance Thick anti-corrosion steel casing extends service life. Removable front panel and washable filter simplify daily inspection. Our factory has over 15 years of HVAC manufacturing experience for reliable quality control.

5.Customizable capacity & wide compatibility Multiple model options cover different airflow and cooling capacities. It supports OEM/ODM on casing color and control panel, fits global voltage standards for worldwide hydronic air conditioning projects.

floor_standing_fan_coil_unit_scene_2010x782
Application Scenarios of Floor Standing Fan Coil Unit
1. Hotel Guest Rooms
The floor standing fan coil unit features easy installation and low noise. It provides stable cooling and heating, perfectly meeting comfortable temperature demands for hotel guest rooms and boutique hotel indoor environments.
2. Office & Commercial Spaces
This floor mounted hydronic fan coil suits various office areas and commercial rooms. With adjustable wind speed, it delivers uniform air supply and creates a comfortable working environment for long-term office use.
3. Building Renovation Projects
Ideal for old building renovation projects without reserved ceiling space. The exposed vertical fan coil unit requires no concealed construction, saving renovation cost and construction time effectively.
4. Classroom & Campus Rooms
Featuring ultra-low operating noise and simple maintenance, the floor standing fan coil unit avoids disturbing teaching and learning. It stably adjusts indoor temperature for school classrooms and offices.
5. Residential & Villa Rooms
Suitable for villas, apartments and family living spaces. The high-efficiency floor fan coil unit achieves fast temperature adjustment, bringing energy-saving and comfortable indoor climate for residential use.
floor_standing_fan_coil_unit_installation_guide_2010x782
Installation Operation Process of Floor Standing Fan Coil Unit

Step 1: Site Checking and Preparation

Check the installation ground flatness, water pipeline interface and power supply condition. Confirm the model, accessories and technical parameters match the design requirements before installation.

Step 2: Unit Positioning and Placement

Place the floor standing fan coil unit on a flat and solid ground. Adjust the foot supports to keep the whole unit vertical and stable to avoid vibration and tilting during operation.

Step 3: Water Pipeline Connection

Connect the chilled and hot water pipes tightly with sealing fittings. Ensure firm connection without water leakage. Keep smooth pipeline layout to guarantee stable water flow and heat exchange performance.

Step 4: Condensate Drainage Installation

Install the drain pipe with standard slope to ensure smooth condensate discharge. Conduct a water leakage test to prevent dripping and indoor water accumulation during long-term operation.

Step 5: Electrical Wiring Connection

Connect power wires and control wires strictly according to the wiring diagram. Ensure reliable grounding and correct circuit connection to avoid electrical failure and hidden safety risks.

Step 6: Commissioning and Trial Operation

Turn on the power and test fan speed, cooling and heating modes. Check for abnormal noise, water leakage and airflow issues. Confirm the floor fan coil unit runs stably at rated performance.

FAQ

1. What are the main differences between floor standing fan coil unit and horizontal concealed FCU?

Floor standing fan coil unit is exposed type without ceiling installation requirement. It is easier for maintenance and perfect for renovation projects, while horizontal FCU needs ceiling space for hidden mounting.

2.Can floor standing fan coil unit work with both 2-pipe and 4-pipe water systems?

3. How to handle condensate drainage for floor standing fan coil unit?

4. What is the noise level range of your floor standing fan coil unit?

5. What regular maintenance does a floor standing fan coil unit require?

Model name:NL-FP

34LM

51LM

68LM

85LM

102LM

136LM

170LM

204LM 

238LM 

nominal air volume(m3/h)

high

340

510

680

850

1020

1360

1700

2040

2380

middle

260

390

520

650

780

1040

1290

1580

1820

low

180

270

360

450

530

710

890

1060

1240

Cooling capacity (w)

high

1800

2700

3600

4500

5400

7200

9000

10800

12600

middle

1620

2450

3240

4050

4850

6480

7980

9580

11200

low

1430

1990

2650

3220

3820

5140

6400

7480

8960

Heating capacity (w)

high

2700

4050

5400

6750

8100

10800

13500

16200

18900

middle

2450

3680

4860

6120

7275

9980

11960

14200

16520

low

2160

3240

4300

5200

6400

8600

9200

10800

12960

Conventional type noise dB(A)

≤35

≤36

≤38

≤40

≤43

≤44

≤45

≤46

≤49

High static press noisiness dB(A)

≤39

≤41

≤43

≤45

≤48

≤49

≤50

≤52

≤54

Input power

(w)

Standard type

41

54

65

82

98

132

168

206

247

Overpressure type

45

58

76

89

110

165

195

228

273

Outlet static press of unit(Pa)

12Pa,30Pa,50Pa

Electric power

Signal phase 220v 50HZ

thermal sink

louvered aluminum thermal sink, spacing of fins is 2.2mm

No. of wind wheel(n)

2

2

2

2

2

2

3

4

4

Heat exchanger

Model

3-row aluminum

Structure model

copper stringing roll  aluminum fin

working pressure

1.2Mpa

water pipe branching

DN20 pipe

condensed water connecting hose

DN20 pipe

water volume (kg/h)

350

480

680

780

910

1140

1270

1320

1460

hydraulic resistance (kpa)

15

20

30

35

45

35

35

38

40

Weight(kg)

Horizontal concealed(WA)

16

19

21

22

23

25

35

38

45

Note:

1.all horizontal concealed type can be equipped with overpressure type(20Pa-30Pa),input power improves 1.5 times than the same grade fan coil with no overpressure.
    

2. The input power means those in high-level air volume.
3.The measure of nominal cooling capacity:room temperature DB t1 is 27℃,WB t2=19.5℃.
4.The measure of nominal cooling capacity:room temperature DB t1 is 21℃, water entering temperature tw is 60℃.
5. Galvanized sheet is used as panel. Please note when ordering if you need fingerprint-proof material as panel.

Previous: 
Next: 
Quick Links
Products Categories

Tel

+86-020-8683-3226

Add

Address I: 901, No.105 Tiangui Road,Huadu District,Guangzhou,China (Marketing Center)
Address II: No. 44 Garden Avenue, Lishui Town, Nanhai District, Foshan City, Guangdong Province (R&D Center & Multi-Factory Base)
Copyright © 2026 NULITE New Energy (Guangzhou) Co., Ltd. All Rights Reserved. Sitemap