| The magnetic levitation inverter water-cooled chiller is an advanced central cooling solution designed for commercial and industrial air conditioning systems. It uses oil-free magnetic levitation compressor technology and intelligent inverter control to provide stable chilled water with high efficiency and low operating noise. Compared with traditional chillers, it helps reduce energy consumption, mechanical friction and maintenance requirements. The unit is suitable for hotels, office buildings, shopping malls, hospitals, factories and data centers that require reliable year-round cooling. With smart control, precise temperature adjustment and excellent part-load performance, it offers a high-efficiency, low-maintenance and environmentally friendly cooling solution for modern HVAC projects. | |||||||||
NL-CXFGH125RT 439kW
Nulite New Energy
NULITE commercial pool heat pumps are designed for hotels, resorts, gyms, and public pools, delivering efficient year-round pool temperature control. Featuring advanced heat pump technology, intelligent temperature compensation, and optimized heat exchange, they reduce operating costs while maintaining high efficiency. The intelligent compressor control automatically adjusts output for stable performance, lower energy use, and longer lifespan. With anti-freeze protection and corrosion-resistant components, they operate reliably outdoors in various climates. Combining energy efficiency, precise temperature control, and durable design, NULITE provides a professional solution for modern pool heating.
The magnetic levitation inverter water-cooled chiller uses advanced oil-free compressor technology to reduce mechanical friction, improve operating efficiency and lower maintenance requirements. With no oil circulation system, the unit helps keep the heat exchanger cleaner and supports stable long-term performance for demanding commercial HVAC projects.
Equipped with intelligent inverter control, the chiller can automatically adjust compressor speed according to real-time cooling demand. This helps improve part-load efficiency, reduce unnecessary power consumption and deliver reliable chilled water output. It is ideal for buildings with changing cooling loads throughout the day.
Designed for central air conditioning systems, the unit provides continuous and stable chilled water for hotels, shopping malls, office buildings, hospitals, factories and data centers. Its water-cooled design improves heat exchange efficiency and supports reliable operation in large-scale commercial and industrial cooling applications.
Magnetic levitation technology allows the compressor rotor to operate without direct mechanical contact, greatly reducing vibration and operating noise. This makes the chiller suitable for noise-sensitive applications such as hotels, hospitals, office towers and high-end commercial buildings that require quiet and comfortable indoor environments.
The chiller can be equipped with intelligent control functions for system monitoring, fault protection and precise temperature adjustment. Multiple protection features help improve operating safety, reduce downtime and simplify daily management. It offers a dependable cooling solution for projects that require efficiency, stability and long service life.
*Compression Components
The compressor consists of first-stage and second-stage impellers, a rotor, a stator, and a high-speed permanent magnet synchronous motor. The two-stage impellers handle initial and final refrigerant compression, while the rotor and stator generate electromagnetic drive force for smooth high-speed operation.
*Magnetic Bearing System
Front and rear radial magnetic bearings support the rotor at both ends through magnetic levitation, eliminating mechanical friction, wear, vibration, and noise. The axial magnetic bearing controls the rotor’s axial position to ensure safe and reliable operation.
*Power Core
The high-speed permanent magnet synchronous motor directly drives the rotor with high efficiency and power density, serving as the power core of the compressor.he high-speed permanent magnet synchronous motor directly drives the rotor with high efficiency and power density, serving as the power core of the compressor.
Magnetic levitation bearings eliminate mechanical contact, resulting in minimal vibration and noise, which creates a quiet and comfortable operating environment for the equipment. This makes the NULITE Magnetic Levitation Inverter Water-Cooled Chiller ideal for noise-sensitive applications such as hospitals, hotels, office buildings, and high-end commercial spaces, where low vibration protects surrounding structures, extends equipment life, and ensures a peaceful atmosphere for occupants while reducing wear and maintenance needs for long-term reliable performance.
The NULITE Magnetic Levitation Inverter Water-Cooled Chiller features three core technologies for superior performance: the blue Oil-Free Magnetic Compressor delivers zero friction, ultra-low vibration, and high efficiency; the Smart PLC Touch Screen on the gray control cabinet provides real-time parameter monitoring and inverter control; and the High-Efficiency Shell & Tube Vessel ensures optimized heat transfer and robust pressure resistance. Together, these components enable the chiller to achieve efficient, intelligent, and stable operation.
Magnetic Levitation Inverter Water-Cooled Chiller. – Front & Rear View
Front View– Clean & Durable Design
On the left side of the front panel is a gray electrical control cabinet equipped with a color LCD touchscreen for real-time monitoring and parameter setting, with a red emergency stop button below the screen for safety. To the right of the cabinet is the blue magnetic levitation centrifugal compressor, connected to black suction piping above in a compact layout. Below is the circular end face of the large black heat exchanger, featuring flanged bolt connections, supported by a sturdy black steel channel base, giving the unit a professional and solid industrial appearance.
Rear View
The side clearly shows the water-side piping system, including the inlet/outlet water flange connections extending from the black cylinder, along with valves, pressure gauges, and sensors, forming a complete cooling water and chilled water circulation loop. The unit adopts a dual-cylinder horizontal layout, with the evaporator and condenser arranged side by side, connected above by compressor discharge piping and electronic expansion valve refrigerant lines. The back is equipped with cable entry holes for main power and control wiring. Ample space is reserved on the sides and back for pipe inspection, sensor calibration, and electrical maintenance, making the overall structure compact and easy to service.
Site Preparation & Unit Positioning
Choose a well-ventilated outdoor location with a stable foundation and enough service space around the unit. Keep the installation area clean, dry, and easy to access for maintenance. Make sure the position is suitable for pool water piping and power connection. Place the commercial air source pool heat pump on a solid base and fix it securely. Ensure the unit is level to support stable operation, and leave enough clearance for airflow intake and discharge to maintain efficient heat exchange performance.
Water Pipe Connection, Electrical Wiring & System Start-Up
Connect the unit to the pool circulation system per the installation diagram. Install inlet/outlet pipes correctly, add valves, a filter, and a circulation pump if needed, and check all joints for leaks. Connect power and control wiring per the manual and local standards; electrical work must be done by a qualified technician. After installation, fill with water, remove air, check water flow, power, and settings, then run a full test to confirm stable heating and correct temperature control.
Large Commercial Complexes
Hospitals & Healthcare Facilities
Data Centers (IDC)
High-End Hotels & Resorts
Industrial Plants & Precision Manufacturing
Commercial buildings have highly variable cooling loads, and this unit's intelligent inverter control adjusts output steplessly based on real-time demand, delivering exceptional part-load efficiency and significantly reducing electricity costs, while its ultra-quiet operation also avoids noise disruption.
Hospitals demand stable temperature and high reliability, and this unit's high-precision sensors and inverter regulation ensure constant outlet water temperature, while the oil-free design prevents lubricant contamination to meet strict indoor air quality and environmental standards, and low vibration and noise benefit wards and diagnostic areas.
Data centers require 24/7/365 uninterrupted cooling, and the magnetic levitation oil-free compressor has no mechanical friction, ensuring long lifespan and high reliability, while soft-start technology reduces grid impact and high efficiency helps lower PUE.
Guest comfort is paramount, and this unit's ultra-quiet operation and stepless inverter regulation provide smooth, silent cooling, while the oil-free, maintenance-free design reduces operating costs and downtime, ensuring year-round operation.
Industries such as electronics, pharmaceuticals, and food processing often require process cooling with tight temperature tolerances, and this unit's wide application range and precise temperature control meet these needs, while its high efficiency and eco-friendly design align with industrial energy-saving and carbon-reduction goals.
What is a magnetic levitation inverter water-cooled chiller?
A magnetic levitation inverter water-cooled chiller is a high-efficiency central cooling unit using oil-free magnetic bearing compressor technology. It provides stable chilled water for commercial and industrial HVAC systems. Compared with traditional chillers, it offers lower friction, quieter operation, better part-load efficiency and reduced maintenance requirements.
What is the typical chilled water outlet temperature?
The typical chilled water outlet temperature can be adjusted according to project requirements, commonly around 5°C to 15°C for air conditioning applications. The actual temperature range depends on the specific model, system design and cooling demand. Please refer to the technical datasheet for accurate operating parameters.
What operating conditions does the unit require?
As a water-cooled chiller, the unit is usually installed in an equipment room and works with a cooling tower, chilled water pump and cooling water pump. Stable water flow, proper ventilation, suitable cooling water temperature and correct electrical connection are important for safe and efficient operation.
Does the magnetic levitation chiller need compressor oil?
The magnetic levitation compressor uses an oil-free design, which helps reduce oil-related maintenance and keeps the heat exchanger cleaner over long-term operation. This improves heat exchange efficiency, reduces mechanical wear and supports stable performance for commercial buildings, hospitals, hotels and data centers.
Is the chiller suitable for part-load operation?
Yes. The inverter control system allows the chiller to automatically adjust compressor speed according to real-time cooling demand. This makes it highly suitable for buildings with changing load conditions, such as office buildings, shopping malls and hotels, helping reduce energy consumption during low and medium load periods.
Magnetic Levitation Inverter Water-Cooled Chiller Selection Guide
Pool Volume | Required Heating Capacity (Ref.) | Recommended Model | Heating Capacity | Typical Application |
|---|---|---|---|---|
100–150 m³ | 20–32 kW | NL-G8Y | 32 kW | Small hotel pools, club pools |
150–180 m³ | 30–40 kW | NL-G10Y | 40.5 kW | Medium hotel pools, community pools |
180–220 m³ | 38–48 kW | NL-G12Y | 48.6 kW | Medium public pools, fitness centers |
220–300 m³ | 48–65 kW | NL-G15Y | 65 kW | Large hotel pools, resorts |
300–400 m³ | 65–85 kW | NL-G20Y | 85 kW | Large resort pools |
400–480 m³ | 85–101 kW | NL-G24Y | 101 kW | Large public pools |
480–560 m³ | 101–120 kW | NL-G30Y | 120 kW | Water parks, large public pools |
560–700 m³ | 120–150 kW | NL-G40Y | 150 kW | Large water parks |
700–900 m³ | 150–196 kW | NL-G50Y | 196 kW | Extra-large water parks |
900–1100 m³ | 196–238 kW | NL-G60Y | 238 kW | Extra-large water parks, integrated pool projects |
Unit Model | Model | FLM-CXFGH125RT | FLM-CXFGH150RT | FLM-CXFGH180RT | FLM-CXFGH200RT |
|---|---|---|---|---|---|
Cooling Capacity | RT | 125 | 150 | 180 | 200 |
Cooling Capacity | kW | 439 | 527 | 633 | 703 |
Input Power | kW | 78.15 | 90.7 | 106.2 | 116.9 |
Full Load EER | kW/kW | 5.62 | 5.81 | 5.96 | 6.01 |
Power Consumption Per RT | kW/RT | 0.62 | 0.60 | 0.59 | 0.58 |
IPLV | kW/kW | 9.64 | 9.94 | 9.96 | 10.05 |
Compressor Quantity | Pcs | 1 | 1 | 1 | 1 |
Unit Type | Type | Horizontal | Horizontal | Horizontal | Horizontal |
Starting Method | Type | Variable Frequency Start | Variable Frequency Start | Variable Frequency Start | Variable Frequency Start |
Compression Stage | Type | Two-Stage Compression | Two-Stage Compression | Two-Stage Compression | Two-Stage Compression |
Condenser | |||||
Water Flow | m³/h | 96 | 110 | 135 | 151 |
Water Pressure Drop | kPa | 80 | 83 | 75 | 73 |
Water Connection Size | DN | 150 | 150 | 150 | 200 |
Evaporator | |||||
Water Flow Rate | m³/h | 77 | 92 | 110 | 120 |
Water Pressure Drop | kPa | 82 | 80 | 75 | 72 |
Water Connection Size | DN | 125 | 150 | 150 | 200 |
Unit Dimensions (Longest Side) | |||||
Length | mm | 2800 | 2800 | 3100 | 3100 |
Width | mm | 1700 | 1800 | 1850 | 1900 |
Height | mm | 2040 | 2100 | 2100 | 2200 |
Refrigerant | Type | R134a | R134a | R134a | R134a |
Weight | kg | 3150 | 3500 | 3800 | 4200 |